Thermal's thermocouple probes for higher temperatures are made with inconel sheaths and magnesium oxide insulation. The probe bodies and insulation will withstand temperatures up to 1500°F. Type K and J thermocouple wire is always available for quick shipment; type T is also available but may require longer delivery times. Probe diameters available are .040", .062", .125", .188", and .250". Three types of junctions (sensitive end of probe) are available, as shown below. To order any of our thermocouples, specify configuration number, probe diameter, probe length, junction type, thermocouple type, and lead length (where applicable).
To request a quote via email please use the form at the bottom of the configurations page or just give us a call at 1.800.633.2962.
 |
Exposed Junctions are used for measuring gas temperatures with quick response. Only useful when moisture or other contaminants are not present in the gas. |
| |
 |
Grounded Junctions are used for virtually all applications except where stray electrical signals may leak into the thermocouple conductors. |
| |
 |
Ungrounded Junctions are used when the thermocouple conductors need to be electrically isolated from their environment. |
Last Updated:
April 27, 2009
|